Measurements of alveolar pO2 using 19F-MRI in partial liquid ventilation.

2003

Rationale and Objectives: Partial liquid ventilation using Perfluorcarbon (PFC) is an innovative treatment of acute respiratory distress syndrome. However, the underlying mechanisms are not totally clear. The aim was to investigate the distribution of oxygen partial pressure within the PFC-filled lung (ppO 2 ). Methods: Nine pigs underwent partial liquid ventilation, receiving 20 mL PFC/kg bodyweight (bw). Measurements were obtained by a chemical shift selective TurboFLASH sequence at different axial lung levels. ppO 2 was calculated from 1 9 F-MRI by nonlinear curve T 1 -fitting technique after noise correction. Results: Quantification and distribution of ppO 2 was performed successfully. …

Respiratory Distress SyndromeLungLiquid VentilationChemistryPartial PressureDependent lungGeneral MedicinePartial pressureMagnetic Resonance ImagingLimited accessOxygenPulmonary Alveolimedicine.anatomical_structureFluorocarbon PolymersIn vivoAnesthesiamedicineDistribution (pharmacology)AnimalsRadiology Nuclear Medicine and imagingPartial liquid ventilationPulmonary VentilationPerfusionBiomedical engineeringInvestigative radiology
researchProduct

19F-MRI of perflubron for measurement of oxygen partial pressure in porcine lungs during partial liquid ventilation

2001

A method for in vivo measurement of oxygen partial pressure (pO2) in porcine lungs during partial liquid ventilation (PLV) with perflubron (PFOB) was developed. A pulse sequence for high-resolution MRI of the distribution of PFOB in the lung after intratracheal administration was developed as well. Moreover, quantitative measurements of longitudinal relaxation time T(1) of (19)F resonances for assessment of regional pO2 are described. Due to the need to acquire data during a single expiratory breathhold, only low SNRs were achieved in vivo. Therefore, simulations were performed to investigate the influence of background noise on T(1) values calculated from data with low SNR. Based on these …

medicine.diagnostic_testChemistryPerflubronbusiness.industryMagnetic resonance imagingPartial pressureBackground noisechemistry.chemical_compoundIn vivomedicineRadiology Nuclear Medicine and imagingPartial liquid ventilationRespiratory systemNuclear medicinebusinessLongitudinal Relaxation TimeBiomedical engineeringMagnetic Resonance in Medicine